The Belling BL6501A datasheet details specifications, pin functions, and performance of this single‑phase dual‑current sampling energy measurement chip.
The BL6501A is an energy measurement IC for single-phase two-wire electricity meters. It samples current on both line and neutral inputs and uses the larger of the two currents for metering when an error exceeds 12.5%.
It provides a high-speed CF pulse for metering and data processing, lower-speed F1/F2 pulses for driving a pulse motor or mechanical counter, and REVP/FAULT status outputs. The device operates from a single 5 V supply and includes an on-chip 2.44 V reference. This manual is written in Chinese.
| Supply voltage | 5 V single supply |
|---|---|
| Power consumption | 15 mW typical |
| Reference voltage | 2.44 V ±8% |
| Maximum differential input voltage | ±660 mV |
| Maximum input level | ±1 V |
| Dynamic range accuracy | Average error less than 0.3% in 500:1 dynamic range |
| Operating temperature | -40 to +85 °C |
| Storage temperature | -55 to +150 °C |
| Reference voltage range | 2.245 to 2.635 V |
It uses a single 5 V supply.
The on-chip reference voltage is 2.44 V ±8%.
It samples both line and neutral currents; when their error exceeds 12.5%, FAULT indicates faulty use, and REVP indicates reverse active power.
CF provides a high-speed pulse for metering and data processing, while F1 and F2 provide lower-speed pulses.