This document introduces TOPSwitch's usage techniques, technology and troubleshooting guide
This application note from Power Integrations serves as a comprehensive guide for engineers designing with TOPSwitch integrated off-line switchers. It includes a detailed troubleshooting guide organized by symptom and cause, example power supply circuits for various topologies, and design sections covering drain clamping, PC board layout, transformer design, efficiency optimization, thermal management, control loop compensation, EMI reduction, soft-start techniques, and power factor correction.
The document also provides specific design notes for bias supplies, non-isolated flyback converters, constant-current/constant-power regulation, and DC-DC converters for telecom applications. Reference designs and evaluation boards for TOP200, TOP202, TOP204, and TOP210 devices are listed, along with a TOPFAX form for technical support inquiries.
| Switching frequency | 100 kHz |
|---|---|
| Output rectifier breakdown voltage (TOP100 series) | 400 V |
| Output rectifier breakdown voltage (TOP200 series) | 600 V |
| Clamp Zener voltage rating | 1.5 times reflected output voltage VOR |
Insufficient clamping or high leakage inductance can cause excessive drain-source voltage, as can a transformer primary clamp Zener voltage that is too low.
Use an optocoupler with a current transfer ratio (CTR) between 50% and 200%.