This application note from Power Integrations serves as a comprehensive guide for engineers designing with TOPSwitch integrated off-line switchers. It includes a detailed troubleshooting guide organized by symptom and cause, example power supply circuits for various topologies, and design sections covering drain clamping, PC board layout, transformer design, efficiency optimization, thermal management, control loop compensation, EMI reduction, soft-start techniques, and power factor correction.

The document also provides specific design notes for bias supplies, non-isolated flyback converters, constant-current/constant-power regulation, and DC-DC converters for telecom applications. Reference designs and evaluation boards for TOP200, TOP202, TOP204, and TOP210 devices are listed, along with a TOPFAX form for technical support inquiries.

Read online

Power Integrations AN-14 specifications

Switching frequency100 kHz
Output rectifier breakdown voltage (TOP100 series)400 V
Output rectifier breakdown voltage (TOP200 series)600 V
Clamp Zener voltage rating1.5 times reflected output voltage VOR

Source: Power Integrations TOPSwitch AN-14 Tips, Techniques, and Troubleshooting Guide

All Power Integrations AN-14 documents by type

Questions answered in these manuals

What causes excessive drain-source voltage on the TOPSwitch?

Insufficient clamping or high leakage inductance can cause excessive drain-source voltage, as can a transformer primary clamp Zener voltage that is too low.

From: Power Integrations TOPSwitch AN-14 Tips, Techniques, and Troubleshooting Guide

What is the recommended optocoupler CTR range for TOPSwitch designs?

Use an optocoupler with a current transfer ratio (CTR) between 50% and 200%.

From: Power Integrations TOPSwitch AN-14 Tips, Techniques, and Troubleshooting Guide

What is the recommended optocoupler CTR range for TOPSwitch designs?

The recommended optocoupler current transfer ratio (CTR) is between 50% and 200%.

From: Power Integrations TOPSwitch AN-14 Application Note: Tips, Techniques, and Troubleshooting Guide

How can EMI be reduced in TOPSwitch power supplies?

Use a Zener clamp circuit across the transformer primary and minimize RC damping on primary or secondary windings.

From: Power Integrations TOPSwitch AN-14 Application Note: Tips, Techniques, and Troubleshooting Guide