This document is about the technical application guide of topswitch, which mainly includes the design and use methods of topswitch, as well as solutions to common problems
This application note from Power Integrations covers common technical questions for TOPSwitch power supply controllers. It includes a detailed troubleshooting guide, example power supply circuits, and design guidelines for drain clamping, PC layout, transformer design, efficiency optimization, thermal management, control loop compensation, EMI reduction, soft start, and power factor correction.
The document also provides optocoupler recommendations, input undervoltage lockout circuitry, doubler input techniques, and a TOPFAX form for technical support. It references additional design notes and reference board documentation for further details.
| Switching frequency | 100 kHz |
|---|
The recommended optocoupler current transfer ratio (CTR) is between 50% and 200%.
Use a Zener clamp circuit across the transformer primary and minimize RC damping on primary or secondary windings.
Insufficient clamping or high leakage inductance causing excessive Drain-Source voltage can destroy the TOPSwitch.