This manual describes the hardware information, installation driver and usage methods of ICP DAS ZT-USB series, suitable for users using ICP DAS ZT-USB series products.
The ICP DAS ZT-USB series modules are small-sized wireless ZigBee converters based on the IEEE802.15.4 standard that convert a USB interface to a personal area ZigBee network. The typical transmission range is 60 meters line of sight, with a frequency range of 2.405 GHz to 2.48 GHz, 16 channels, and 16384 PAN IDs.
A Windows-compatible GUI configuration utility is available to set configurations such as PAN ID. The ZT-USBC model acts as a ZigBee coordinator to initialize and manage routing, while the series can also function as a ZigBee router to extend transmission range and improve signal quality.
| Part Number | ZT-USBC (Coordinator) |
|---|---|
| Communication Interface | USB Type-A Plug |
| Compatibility | USB 1.1 and 2.0 standard |
| Power Consumption | 0.3 W (Max.) |
| Dimensions | 19.8 mm x 58.4 mm x 9 mm |
| Operating Temperature | -25°C ~ +75°C |
| Transmit Range | 60 m (Typical) |
| Max. Slaves Supported | 255 |
The typical transmission is 60 meters line of sight.
The driver supports Windows 2000, XP, Vista, 7, and 8.
One ZigBee network can manage 255 ZigBee routers.
Maximum power consumption is 0.3 W.