Winsen ZP201 Refrigerant Gas Detection Module User Manual

ZP201 refrigerant gas detector module adopts advanced multilayer thick film manufacturing process semiconductor gas sensitive element, the gas sensitive element contains filter adsorption layer to reduce the interference of alcohol and other gases, has extremely high sensitivity to refrigerant gas, the module is aged, calibrated, calibrated, has good consistency and extremely high sensitivity.


Winsen ZP201 Refrigerant Gas Detection Module User Manual - cover page
Brand
Winsen
Category
sensor
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
365 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
C69D38D75858CC85B552EAE8E81EF237

About this manual

The ZP201 is a refrigerant gas detection module from Zhengzhou Winsen Electronic Technology Co., Ltd. It uses a multilayer thick-film semiconductor gas sensor element with a filter adsorption layer to reduce interference from gases such as alcohol, and it is aged, calibrated and adjusted at the factory. It is intended for refrigerant leak detection in air conditioners and refrigeration systems.

The module detects R32 refrigerant gas and provides a PWM signal output. Its operating voltage is 5.0±0.2 V DC, operating current is ≤80 mA, factory-set alarm concentration is 5000 ppm, and dimensions are 25×34×14.1 mm. The manual also defines the five pins, PWM output states for warm-up, operation, alarm and fault, and precautions for handling and installation. This manual is written in Chinese.

What's inside

  • Declaration
  • Product Description
  • Module Features
  • Main Applications
  • Technical Specifications
  • Pin Definitions
  • Output Signal Definitions
  • Precautions

Specifications

ModelZP201
Detected gasRefrigerant gas R32
Signal outputPWM
Operating voltage5.0±0.2 V DC (no reverse-voltage protection)
Operating current≤80 mA
Warm-up time≤3 minutes
Alarm concentration5000 ppm
Operating temperature0 to 50°C
Operating humidity≤95%RH
Storage temperature-20 to 60°C
Storage humidity≤60%RH
Dimensions25×34×14.1 mm (L×W×H)

Frequently asked questions

What refrigerant gas does the ZP201 detect?

It detects R32 refrigerant gas.

What type of output does the ZP201 provide?

It provides a PWM signal output and requires an external pull-up resistor.

What happens when the module enters the alarm state?

It remains in the alarm state and does not switch to other states.

What supply voltage does the ZP201 require?

It operates at 5.0±0.2 V DC and has no reverse-voltage protection.