MC101B catalytic combustion type gas sensor works according to the principle of catalytic combustion effect. The sensor consists of a sensor element and a compensation element paired to form an arm of a bridge. When the combustible gas is met, the sensor element resistance increases and the bridge output voltage changes. The change in voltage is proportional to the increase in gas concentration. The compensation element serves as a reference and temperature and humidity compensation.
This is the Chinese-language user manual, version 1.5 dated 2021-07-16, for the MC101B catalytic combustion gas sensor made by Zhengzhou Winsen Electronic Technology Co., Ltd. It explains how the sensor works: a detecting element and a compensating element form one arm of a bridge circuit, and the bridge output voltage rises in proportion to combustible gas concentration, while the compensating element provides reference and temperature/humidity compensation.
The manual lists the sensor's features, its main applications for leak alarm or concentration detection of natural gas, liquefied gas and coal gas in non-industrial public places, and a full technical specification table. Later pages show sensitivity, response-recovery, temperature, humidity, supply-voltage and long-term stability curves, and give detailed precautions on conditions to avoid, storage, and hand soldering conditions. This manual is written in Chinese.
| Product type | Catalytic combustion gas sensor |
|---|---|
| Standard package | Plastic package |
| Operating voltage | 3.0 ± 0.1 V |
| Operating current | 110 ± 10 mA |
| Sensitivity (1% methane) | 20 to 45 mV |
| Sensitivity (1% propane) | 30 to 70 mV |
| Measurement range | 0 to 100 %LEL |
| Response time (90%) | ≤10 s |
| Recovery time (90%) | ≤30 s |
| Operating environment | -40 °C to +70 °C, below 95%RH |
| Storage environment | -20 °C to +70 °C, below 95%RH |
The sensor operates at 3.0 ± 0.1 V and 110 ± 10 mA.
It is used for leak alarm or concentration detection of combustible gases such as natural gas, liquefied gas and coal gas in non-industrial public places.
Hand soldering with a constant-temperature iron is preferred, using a rosin flux with minimum chlorine content, at no more than 350 °C for no more than 5 seconds.
In clean air the absolute value of zero drift is less than 2 mV per year, and the sensitivity (1% CH4) drift is also less than 2 mV per year.