Winsen MC101B Catalytic Combustion Gas Sensor User Manual

MC101B catalytic combustion type gas sensor works according to the principle of catalytic combustion effect. The sensor consists of a sensor element and a compensation element paired to form an arm of a bridge. When the combustible gas is met, the sensor element resistance increases and the bridge output voltage changes. The change in voltage is proportional to the increase in gas concentration. The compensation element serves as a reference and temperature and humidity compensation.


Winsen MC101B Catalytic Combustion Gas Sensor User Manual - cover page
Brand
Winsen
Category
sensor
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
447 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
B1A1CCF3B42857DE07B80E9F7F2BCDBE

About this manual

This is the Chinese-language user manual, version 1.5 dated 2021-07-16, for the MC101B catalytic combustion gas sensor made by Zhengzhou Winsen Electronic Technology Co., Ltd. It explains how the sensor works: a detecting element and a compensating element form one arm of a bridge circuit, and the bridge output voltage rises in proportion to combustible gas concentration, while the compensating element provides reference and temperature/humidity compensation.

The manual lists the sensor's features, its main applications for leak alarm or concentration detection of natural gas, liquefied gas and coal gas in non-industrial public places, and a full technical specification table. Later pages show sensitivity, response-recovery, temperature, humidity, supply-voltage and long-term stability curves, and give detailed precautions on conditions to avoid, storage, and hand soldering conditions. This manual is written in Chinese.

What's inside

  • Product Description
  • Sensor Features
  • Main Applications
  • Technical Specifications
  • Sensitivity and Response-Recovery Characteristics
  • Output Signal vs Temperature, Humidity and Supply Voltage
  • Long-term Stability
  • Usage Precautions
  • Soldering Conditions
  • Contact Information

Specifications

Product typeCatalytic combustion gas sensor
Standard packagePlastic package
Operating voltage3.0 ± 0.1 V
Operating current110 ± 10 mA
Sensitivity (1% methane)20 to 45 mV
Sensitivity (1% propane)30 to 70 mV
Measurement range0 to 100 %LEL
Response time (90%)≤10 s
Recovery time (90%)≤30 s
Operating environment-40 °C to +70 °C, below 95%RH
Storage environment-20 °C to +70 °C, below 95%RH

Frequently asked questions

What is the operating voltage and current of the MC101B sensor?

The sensor operates at 3.0 ± 0.1 V and 110 ± 10 mA.

What gases is the MC101B used to detect?

It is used for leak alarm or concentration detection of combustible gases such as natural gas, liquefied gas and coal gas in non-industrial public places.

What soldering conditions are recommended?

Hand soldering with a constant-temperature iron is preferred, using a rosin flux with minimum chlorine content, at no more than 350 °C for no more than 5 seconds.

How stable is the sensor's zero point over time?

In clean air the absolute value of zero drift is less than 2 mV per year, and the sensitivity (1% CH4) drift is also less than 2 mV per year.