MC107B catalytic combustion gas sensor works on the principle of catalytic combustion effect, by combining the detection element and the compensation element to form a bridge arm, when combustible gas is detected, the resistance of the detection element increases, and the bridge output voltage changes.
This is the Chinese user manual (version 1.4B) from Zhengzhou Winsen Electronic Technology for the MC107B catalytic combustion gas sensor. The sensor works on the catalytic combustion principle: a detecting element and a compensating element form one arm of a bridge circuit, and the bridge output voltage rises proportionally with combustible gas concentration. The manual covers the product description, features, main applications, technical specifications, basic test circuit and characteristic curves for sensitivity, response/recovery, temperature, humidity, supply voltage and long-term stability.
The last part lists usage precautions: conditions that must be avoided (volatile silicon compounds, highly corrosive gases, alkali and halogen contamination, water, freezing, excessive supply voltage), conditions to avoid where possible (condensation, high gas concentration, long storage, extreme environments, vibration, shock), and recommended hand-soldering conditions. The document ends with the company address and contact details. This manual is written in Chinese.
| 产品类型 | 催化燃烧式气体传感器 |
|---|---|
| 标准封装 | 塑料座金属封装 |
| 工作电压 | 2.5±0.1 V |
| 工作电流 | 150±10 mA |
| 灵敏度 (1% 甲烷) | 15~45 mV |
| 测量范围 | 0~100 %LEL |
| 响应时间 (90%) | ≤10 s |
| 恢复时间 (90%) | ≤30 s |
| 使用环境 | -40~+70℃, below 95%RH |
| 储存环境 | -20~+70℃, below 95%RH |
It can be used in commercial areas for leak alarms or concentration detection of combustible gases such as natural gas, liquefied gas and coal gas.
Hand soldering with a constant-temperature iron at no more than 350℃ for no more than 5 seconds, using a rosin flux with minimal chlorine content.
In clean air the absolute drift is less than 2mV per year for the zero point and less than 2mV per year for sensitivity (1% CH4).
Exposure to volatile silicon compound vapor, highly corrosive gases, alkali/halogen contamination, water, freezing and supply voltages above the rated value.