This document introduces the principles to follow when choosing a HEM 115 electromagnetic clutch or brake.
The Hitex HEM 115 brake and HEM 105 clutch document provides selection guidance for electromagnetic clutches and brakes. It explains how to calculate required torque, choose a service factor, and read operating times for DC and AC switching.
Technical data tables list torque ratings, maximum speeds, input power, operating times, displacements and dimensions for the HEM 115 brake and HEM 105 clutch designs 1 and 3. An installation example shows DC and AC side switching, and the final page lists HITEX product groups and contact details.
| Torque range | 7.5 – 480 Nm |
|---|---|
| Available supply voltages | 24, 96 and 190 VDC |
| Brake type | DC electromagnetic brake |
| Clutch type | DC electromagnetic clutch |
| Mounting | Flange mounted |
| Backlash | Backlash-free |
| Maintenance | Maintenance free |
The HEM range is available in 24, 96 and 190 VDC.
The required torque is calculated with the formula TN (Nm) = 9550 · P (kW) / n (rpm).
The engagement time is prolonged by approximately factor 10 for AC switching.
The guideline lists a service factor of 2.0 for low masses, equal loading and non-intermittent operation.