HARTING RF-R400 RFID Reader Assembly Manual

This document is the assembly manual for HARTING RFID reader RF-R400, which introduces the performance features, installation, terminal connection, etc. of the reader.


HARTING RF-R400 RFID Reader Assembly Manual - cover page
Brand
HARTING
Category
Industrial Supply
Document type
Installation Guide
Language
English
Pages
26
File format
PDF
File size
818 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
4CBC06B6A661154E482ED0FB9494D788

About this manual

This assembly manual describes the installation and setup of the HARTING Ha-VIS RF-R400 UHF RFID reader. It covers safety instructions, performance features, mounting, terminal connections, operating elements, and radio approvals for European and North American versions.

The document details antenna connections with SMA connectors, power supply requirements (24 V DC ±20%), Ethernet and USB interfaces, digital I/O, relay output, status LEDs, reset button, and reader power adjustment. It also lists approved antennas for FCC/IC compliance and provides part numbers for EU and US reader types.

What's inside

  • About this manual
  • Performance features of reader family Ha-VIS RF-R400
  • Installation
  • Terminals
  • Operating and display elements
  • Radio approvals

Specifications

Operating frequencyUHF range
Output power range0.1 W to 2 W
Maximum read range12 m
Power supply24 V DC ±20%
Antenna impedance50 Ω
Antenna connector torque0.45 Nm
Ethernet interface10/100Tbase M12
USB interfaceUSB Mini
Digital I/ODigital inputs and digital output
Relay outputRelay output and RS232
Reader typesEU (20911071101) and US (20911071102)

Frequently asked questions

What is the output power range of the HARTING RF-R400 reader?

The output power is configurable between 0.1 Watt and 2 Watts.

What are the available reader types for the Ha-VIS RF-R400?

Two versions are available: Ha-VIS RF-R400-EU for Europe and Ha-VIS RF-R400-US for North America and Asia.

What is the required power supply voltage for the RF-R400?

The reader requires a 24 V DC power supply with ±20% tolerance.