This document is the assembly manual for HARTING RFID reader RF-R400, which introduces the performance features, installation, terminal connection, etc. of the reader.
This assembly manual describes the installation and setup of the HARTING Ha-VIS RF-R400 UHF RFID reader. It covers safety instructions, performance features, mounting, terminal connections, operating elements, and radio approvals for European and North American versions.
The document details antenna connections with SMA connectors, power supply requirements (24 V DC ±20%), Ethernet and USB interfaces, digital I/O, relay output, status LEDs, reset button, and reader power adjustment. It also lists approved antennas for FCC/IC compliance and provides part numbers for EU and US reader types.
| Operating frequency | UHF range |
|---|---|
| Output power range | 0.1 W to 2 W |
| Maximum read range | 12 m |
| Power supply | 24 V DC ±20% |
| Antenna impedance | 50 Ω |
| Antenna connector torque | 0.45 Nm |
| Ethernet interface | 10/100Tbase M12 |
| USB interface | USB Mini |
| Digital I/O | Digital inputs and digital output |
| Relay output | Relay output and RS232 |
| Reader types | EU (20911071101) and US (20911071102) |
The output power is configurable between 0.1 Watt and 2 Watts.
Two versions are available: Ha-VIS RF-R400-EU for Europe and Ha-VIS RF-R400-US for North America and Asia.
The reader requires a 24 V DC power supply with ±20% tolerance.