Fuji Electric FSS Ultrasonic Flow Meter Detector Instruction Manual

This is a manual for Fuji Electric Ultrasonic flow meter


Fuji Electric FSS Ultrasonic Flow Meter Detector Instruction Manual - cover page
Brand
Fuji Electric
Category
flow transmitter
Document type
User Manual
Language
English
Pages
50
File format
PDF
File size
3.4 MB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
C6D700F337F2E27314120997953E4057

About this manual

This instruction manual covers the installation, operation, checkup, and maintenance of the Fuji Electric Ultrasonic Flow Meter Detector (Type FSS) and Signal Cable (FLY). It details safety precautions, installation location requirements, and specific mounting procedures for various detector types including FSSA, FSSC, FSSE, FSSD, and FSSH.

What's inside

  • Introduction
  • Safety Precautions
  • Caution on Installation Location
  • Product Outline
  • Installation
  • Mounting of FSSA Type
  • Mounting of FSSC Type
  • Mounting of FSSE Type
  • Check and Maintenance
  • Specifications

Specifications

Ambient Temperature (Detector)-20 to +60°C
Ambient Humidity (Detector)90% RH or less
Ambient Temperature (FSSE)-20 to +60°C
Ambient Humidity (FSSE)100% RH or less

Frequently asked questions

What acoustic coupler should be selected for ordinary cases?

Silicone rubber (A) should be selected for the acoustic coupler in ordinary cases.

What is the maximum ambient temperature for the detector?

The detector can operate in an ambient temperature of up to +60°C.

How often should the unit be inspected?

The unit should be inspected every day to ensure good measurement results.

How frequently is periodic maintenance required for silicone-free grease?

Maintenance, including cleaning and refilling, is required approximately once every 6 months.

Download PDF (3.4 MB)