Signet 2450 Pressure Sensor User Manual

The 2450 Pressure Sensor is a pressure sensor with a one-piece injection molded PVDF body and a ceramic diaphragm for superior compatibility in corrosive liquids.


Signet 2450 Pressure Sensor User Manual - cover page
Brand
Signet
Category
Other Electronics
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
469 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
1E3DE816C637597EBCC4C7EF916AA655

About this manual

The Signet 2450 Pressure Sensor is a gauge pressure sensor designed for use in corrosive liquids. It features a one-piece injection molded PVDF body and a ceramic diaphragm. The sensor offers Digital (S 3L) output or a field-scalable 4 to 20 mA output and is available with three pressure ranges for optimal measurement resolution. It includes built-in temperature compensation and is available with 1/2 in. union process connections suitable for in-line installations.

What's inside

  • Safety Information
  • Specifications
  • Installation Recommendations
  • Tank Installation Options
  • In-line Remote Assembly
  • Integral Assembly
  • Wiring
  • Standards and Approvals

Specifications

Wetted materials (housing)PVDF
Wetted materials (diaphragm)Ceramic
Process connection1/2 in. Union male thread
Rear connection3/4 in. NPT male thread
Standard cable length4.6 m (15 ft)
Sensor Accuracy±1% of full scale @ 25 °C
Operating temperature-15 °C to 85 °C
Digital (S 3L) output power5 to 6.5 VDC ±10%
4 to 20 mA output power12 to 24 VDC ±10% regulated

Frequently asked questions

What materials are the sensor housing and diaphragm made of?

The sensor housing is made of PVDF and the diaphragm is made of ceramic.

What is the standard cable length for the sensor?

The standard cable length is 4.6 meters (15 feet).

What is the sensor accuracy specification?

The sensor accuracy is ±1% of full scale at 25 °C.