SIGNET 5600 Batch Controller Instructions

SIGNET 5600 Batch Controller Instructions


SIGNET 5600 Batch Controller Instructions - cover page
Brand
Signet
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
166 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
2D9F7015FDFE670C833294AC8A38D53D

About this manual

This manual provides instructions for the SIGNET 5600 Batch Controller, a device used to control batching processes. It details the setup of power connections and compatible sensor wiring, including specific configurations for Vortex sensors and open collector sensors. The document emphasizes safety precautions, such as removing power before wiring and isolating AC power lines from signal lines to prevent noise interference.

What's inside

  • Dial Selection
  • Power Connection
  • Compatible Sensor Wiring
  • Batch Contact Wiring
  • Remote Control Wiring
  • End of Batch/Counter Pulse Output Wiring
  • Option Contact Wiring
  • Current Output Wiring
  • Operation Modes
  • Menu Functions

Specifications

Maximum alarm contact ratings5 A @ 30 VDC, 5 A @ 125 VAC, or 3 A @ 250 VAC
Power supply range12 - 24 VDC OR 12 - 24 VAC
Maximum loop impedance (12V supply)350 Ω
Maximum loop impedance (24V supply)950 Ω
Remote control cable length30 m (100 ft)

Frequently asked questions

What is the maximum alarm contact rating?

The maximum ratings are 5 A @ 30 VDC, 5 A @ 125 VAC, or 3 A @ 250 VAC.

What power supply is compatible with the 5600?

The instrument accepts 12 - 24 VDC or 12 - 24 VAC power.

How long can the remote control cable be?

The manual recommends using 4-conductor shielded cable for remote control lines up to 30 m (100 ft) max.