This document provides step-by-step instructions for installing the Signet 8860 dual channel conductivity/resistivity controller. It covers panel mounting, wiring connections, and safety precautions. The controller supports two independent sensor inputs and features multiple output types including 4-20 mA, relay, and open-collector outputs. Electrical specifications include dual power options (AC or DC) and environmental ratings for industrial use.

The guide also includes sensor compatibility details, display options, and relay configuration settings. Safety warnings are emphasized, including disconnecting power before wiring and protecting live contacts to avoid shock hazards.

What's inside

  • Installation Steps
  • Wiring Connections
  • Sensor Input Specifications
  • Output Types
  • Electrical Requirements
  • Environmental Ratings
  • Relay and Open Collector Functions
  • Display Options
  • Safety Precautions

Specifications

Compatible ElectrodesSignet 2818 to 2823 (Standard or Certified Cond/Resist Sensors)
Enclosure RatingNEMA 4X/IP65 front (NEMA 4X Rear cover available)
DisplayAlphanumeric 2 x 16 LCD
Conductivity Range0.01 μS/cm to 400 000 μS/cm
Resistivity Range10 kΩ·cm to 100 MΩ·cm
Power Requirements3-8860-AC: 100 to 240 VAC ± 10%, 50 to 60 Hz, 20VA or 11 to 24 VDC ±10%, regulated, 0.5 A max
Output TypeThree 4 to 20 mA outputs, open-collector, relay
Ambient Operating Temperature-10 °C to 55 °C (14 °F to 131 °F)
Relative Humidity0 to 95%, non-condensing
Standards and ApprovalsCE, EN61326, EN61010, UL listed, ISO 9001, ISO 14001, OHSAS 18001

Frequently asked questions

What are the power requirements for the Signet 8860?

The 8860-AC model requires 100 to 240 VAC ± 10%, 50 to 60 Hz, 20VA or 11 to 24 VDC ±10%, regulated, 0.5 A max. The 8860 model requires 11 to 24 VDC ±10%, regulated, 0.5 A max.

What is the maximum cable length for resistivity measurements?

The maximum cable length for resistivity measurements above 10 MΩ is 25 ft, and solution temperatures must be between 20 °C and 100 °C.

What is the display type and contrast adjustment?

The display is an alphanumeric 2 x 16 LCD with user-selectable contrast in 5 levels.