This document is the 5800 LXT DOWNFLOW/UPFLOW service manual, which mainly introduces the configuration method, system type, salt setting and other information of the device.
This service manual provides detailed instructions for installing, operating, and troubleshooting the FLECK 5800 LXT control valve for both downflow and upflow systems. It includes setup guidelines, wiring diagrams, dimensional drawings, and safety warnings. The manual also covers system configuration, meter selection, drain line sizing, and electrical requirements. Installation must comply with local plumbing and electrical codes, and the unit is designed for potable water systems only.
The document includes tables for system specifications, control programming settings, and flow data. It warns against installing the unit in freezing or high-temperature environments and emphasizes the need for proper voltage and pressure ratings. Safety precautions, such as using PTFE tape and avoiding soldering near drain fittings, are also detailed.
The maximum pressure rating is 125 psi (8.6 bar), though daytime pressure can exceed 80 psi if a regulator is installed.
The unit must not be installed where temperatures drop below 32°F (0°C) or rise above 125°F (52°C).
The controller requires an uninterrupted alternating current (120 VAC) supply to operate.