Fleck 2900 Series Water Softener Service Manual

This document is the service manual for the Fleck 2900 series of products. It includes installation, startup, time adjustment, component disassembly and other content, and is suitable for maintenance personnel of this series of products.


Fleck 2900 Series Water Softener Service Manual - cover page
Brand
Fleck
Category
Water heater
Document type
Service Manual
Language
Spanish
Pages
52
File format
PDF
File size
4.9 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
9E25A740698D541C2AB05D9B97819752

About this manual

This document is a service manual for the Fleck 2900 Series water softener. It provides detailed instructions for installation, including requirements for water pressure, electrical supply, and plumbing codes. The manual specifies operating limits, such as a minimum water pressure of 20 psi and a maximum of 125 psi, and warns against freezing conditions. This manual is written in Spanish.

What's inside

  • Instalación
  • Instrucciones para comenzar
  • Procedimiento de ajuste del temporizador
  • Ensamblaje de temporizador y reloj fechador
  • Ensamblaje de la válvula de control
  • Sistema de salmuera
  • Medidor de latón de 2"
  • Válvula de seguridad de salmuera
  • Resolución de problemas
  • Diagramas de flujo

Specifications

Minimum water pressure20 psi (1.4 bar)
Maximum water pressure125 psi (8.6 bar)
Maximum water temperature110 °F (43 °C)
Drain pipe size (residential)1/2 inches (13 mm)
Drain pipe size (high flow)3/4 inches (19 mm)

Frequently asked questions

What is the minimum water pressure required for the Fleck 2900?

A minimum of 20 psi (1.4 bar) is required for the regeneration valve to function effectively.

What is the maximum water pressure allowed?

The water pressure must not exceed 125 psi (8.6 bar).

What type of lubricant should be used for O-rings?

Only silicone lubricant should be used for the distributor and tank O-rings.