Start here

Fleck 5800 LXT Water Softener Control Service Manual

Fleck 5800 LXT Water Softener Control Service Manual

Service Manual 20 pages · 2 MB · EN

This document serves as a service manual for the Fleck 5800 LXT downflow/upflow water softener control. It provides detailed instructions for dealer use, including system configuration charts, job specification sheets, and installation procedures for the control valve, powerhead, meter, and bypass valves. The manual emphasizes safety precautions regarding water pressure, temperature, and electrical connections.

Read online

FLECK 5800 LXT specifications

Operating Voltage120 VAC
Control Voltage12 VDC
Minimum Water Pressure20 psi (1.4 bar)
Maximum Water Pressure125 psi (8.6 bar)
Maximum Water Temperature110°F (43°C)
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature125°F (52°C)
Drain Line Size (Residential)1/2" (13 mm)

Source: Fleck 5800 LXT Water Softener Control Service Manual

All FLECK 5800 LXT documents by type

Questions answered in these manuals

What happens if power is interrupted for more than 8 hours?

The controller may lose the time setting and it must be re-entered when power is restored.

From: Fleck 5800 LXT Water Softener Control Service Manual

How can a regeneration be triggered immediately?

Press and hold the Extra Cycle button for five seconds.

From: Fleck 5800 LXT Water Softener Control Service Manual

What is the minimum water pressure required for the regeneration valve to operate effectively?

A minimum of 20 pounds (1.4 bar) of water pressure is required for the regeneration valve to operate effectively.

From: Fleck 5800 LXT & SXT Downflow/Upflow Service Manual

What are the maximum limits for water pressure, water temperature, and freezing conditions?

Water pressure must not exceed 125 psi (8.6 bar), water temperature must not exceed 110°F (43°C), and the unit cannot be subjected to freezing conditions.

From: Fleck 5800 LXT & SXT Downflow/Upflow Service Manual

What is the maximum water pressure rating for this unit?

The maximum pressure rating is 125 psi (8.6 bar), though daytime pressure can exceed 80 psi if a regulator is installed.

From: FLECK 5800 LXT Downflow/Upflow Service Manual

What are the minimum and maximum water temperatures for installation?

The unit must not be installed where temperatures drop below 32°F (0°C) or rise above 125°F (52°C).

From: FLECK 5800 LXT Downflow/Upflow Service Manual