This manual introduces the installation manual of 6600-AS automatic synchronized illuminators.
This manual provides step-by-step instructions for installing Fiberstars 6600-AS automatic synchronized illuminators. It covers electrical wiring, color wheel synchronization, fiber optic port assembly, and grounding requirements. Safety warnings include not installing within 1.5 meters of pools or hot tubs. The guide also details fiber termination procedures for 450 or 600-fiber configurations, including heat knife trimming and constant color rod installation.
| Voltage Required | 120VAC 60Hz |
|---|---|
| Power Consumption | 200 Watts |
| Start Current Load | 4.4 amps |
| Current Usage | 1.8 amps |
| Lamp Type | Metal-Halide, proprietary design |
| Lamp Life | 6000 hrs average |
| Cool Down Restrike Period | 3 minutes |
| Weight | 20 lbs |
| Maximum Soil Height | Do not allow fill to exceed this level |
It takes about 15 seconds for the color wheels to rotate to the home position.
Always turn the color wheels OFF before shutting down the system so they return to the home position on the next startup.
No, do not use dimmable relays on Metal Halide lamps.