Extech EZ40 Combustible Gas Leak Detector User's Guide

The Extech EZ40 Combustible Gas Leak Detector detects the presence of combustible gas and nuisance vapors (Natural Gas, Methane, Ethane, Propane, Butane, Acetone, Alcohol, Ammonia, Steam, Gasoline, Jet Fuel, Hydrogen Sulfide, Smoke, Industrial Solvents, Lacquer Thinner, Naphtha) in concentrations as low as 10% LEL for Methane and alerts the user with audible and visual alarms.


Extech EZ40 Combustible Gas Leak Detector User's Guide - cover page
Brand
EXTECH
Category
Other Electronics
Document type
User Manual
Language
English
Pages
5
File format
PDF
File size
135 KB
Published
18 October, 2023
Updated
18 October, 2023
Model
EZ40
MD5 checksum
8424A7556B5EC3AABA6982603E5A2D0C

About this manual

The Extech EZ40 Combustible Gas Leak Detector is designed to detect the presence of combustible gas and nuisance vapors, such as methane, natural gas, and various solvents. It features a 16-inch flexible gooseneck for accessing difficult locations and alerts the user with both audible and visual alarms when gas concentrations reach 10% LEL for methane.

The manual details the operational procedures, including a 5-minute warm-up cycle, automatic zeroing, and leak detection techniques using the sensitivity adjustment dial. It also covers maintenance requirements, such as battery replacement with three 'C' batteries, cleaning instructions, and storage conditions to ensure reliable performance.

What's inside

  • Introduction
  • Description
  • Operation
  • Warm-up
  • Zero
  • Earphone Jack
  • Leak Detection
  • Maintenance
  • Battery Replacement
  • Specifications

Specifications

Sensitivity50 ppm methane
Alarm Threshold10% LEL (40% max) for Methane
Warm-up TimeApprox. 5 minute
Response TimeLess than 2 seconds (up to 40% LEL)
Power Supply3 x "C" 1.5V alkaline batteries
Battery LifeApprox. 8 hours continuous use typical
Operating Temperature32 to 122 oF (0 to 50oC)
Dimensions8.7 x 2.83 x 1.8" (221 x 72 x 46mm)

Frequently asked questions

What gases can the EZ40 detect?

The EZ40 detects Natural Gas, Methane, Ethane, Propane, Butane, Acetone, Alcohol, Ammonia, Steam, Gasoline, Jet Fuel, Hydrogen Sulfide, Smoke, Industrial Solvents, Lacquer Thinner, Naphtha, and Carbon Monoxide (indication only).

How long does the warm-up cycle take?

The typical warm-up and self-zero cycle takes approximately 5 minutes.

What batteries are required for the EZ40?

The unit requires three "C" 1.5V alkaline batteries.

What is the warranty period for the instrument?

Extech warrants the instrument to be free of defects in parts and workmanship for one year from the date of shipment.