This document is the instruction manual of Elma DT128, which introduces the function and usage of Elma DT128.
The Elma DT128 is a non-contact moisture meter designed for detecting moisture in building materials like plaster, cement, and wood. It uses high-frequency measurement principles and displays results in percentage material humidity. The device features a white backlight LCD, alarm settings for 'RISK' (30% default) and 'WET' (60% default) thresholds, and auto-shutdown after 30 seconds of inactivity. Calibration is required upon first use and before moving to a new location. The meter can measure up to 40mm depth and includes a data hold function for reading values.
Operation involves turning on the device, pressing the MEAS button to start measuring, and calibrating by holding the sensor in open air until the display shows a value under 0.5%. Alarm settings can be adjusted using the UP/DOWN buttons and confirmed with the SET button. The meter beeps to alert users when moisture levels exceed set thresholds.
| Measuring Range | 0.0 – 100.0 |
|---|---|
| Penetration Depth | 20–40mm |
| Resolution | 0.1 |
| Battery | 3 x AAA batteries |
The device displays a 'BAT' symbol on the screen to indicate low battery.
The measurement depth is 20-40mm.
The default RISK alarm setting is 30.
It displays 'BAT' on the screen.