Elma DT 178A Data Logger User Manual

This is a document describing the user manual for Elma DT 178A products


Elma DT 178A Data Logger User Manual - cover page
Brand
ELMA
Category
Other Electronics
Document type
User Manual
Language
DA
Pages
24
File format
PDF
File size
1.1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
BA21DAFA296AE2CDF96534A9776595BB

About this manual

This manual provides instructions for the Elma DT 178A, a device designed to record acceleration data from shocks and vibrations. It covers safety information, functional descriptions, and specifications including a ±18g acceleration range and 0Hz – 60Hz frequency range. The device features a MEMS semiconductor sensor and a 4Mbit FLASH memory card.

What's inside

  • Safety information
  • Function description
  • Specifications
  • Product description
  • LED indication
  • Operating instructions
  • Installation instructions
  • Software installation and operation

Specifications

Acceleration range±18g
Acceleration resolution0,00625g
Calibrated accuracy±0,5g
Frequency range0Hz – 60Hz
Data memory4Mbit FLASH
Sampling range1 sek. – 24 timer
Power supply3,6V battery
Battery lifeCa. 400 hours
PC InterfaceUSB

Frequently asked questions

What is the Elma DT 178A used for?

It is produced to record acceleration data from shocks and vibrations.

How do I start the logger manually?

Press the black push button for 2 seconds to start the data logger.

What happens when the memory is full?

The red and green LEDs will blink every 60 seconds.

What is the operating temperature range?

The function temperature and humidity range is 0°C - 40°C / 10%RH – 90%RH.