Key facts
- Manuals
- 182
- Models
- 9
- Languages
- ZH · EN · PT
- Last added
- 2026-10-03
Health Care models by brand
Featured Health Care manuals

Sanofi Frisium 10 mg Tablet Patient Information Leaflet
Frisium 10 mg tablets contain the benzodiazepine clobazam and are indicated for short‑term severe anxiety, epilepsy and certain psychiatric disorders. The medication works by calming brain activity and is supplied as white round tablets in a 30‑tablet blister pack.
The leaflet outlines important safety information, including contraindications, drug‑interaction warnings, dosage guidance for adults, children (6 years and older) and the elderly, and instructions on what to do if a dose is missed, how to stop treatment, and how to store the product safely. This manual is written in Chinese.
Covers: Indications · Contraindications · Warnings and Precautions · Drug Interactions · Dosage and Administration · Side Effects

Instech Model 100 Syringe Infusion Pump Operations Manual
This manual explains how to install, program, and operate the Instech Model 100 syringe infusion pump. It includes safety warnings, detailed descriptions of the pump’s front and back panels, menu navigation, and step‑by‑step procedures for loading syringes, setting infusion modes, and delivering medication.
Key sections cover general specifications, alarm and alert handling, battery operation, IV‑pole mounting, cleaning, and service warranty information, plus appendices with flow‑rate tables, syringe size data, and occlusion force values.
Covers: Introduction and Warnings · General Specifications · General Description / Diagram, Alarms/Alerts · Getting Started · Syringe Loading Instructions · Infusion Settings

Bair Hugger 750 Temperature Management Device User Manual
The Bair Hugger 750 is a Total Temperature Management™ system that includes an inflatable temperature management unit, disposable blankets, patient warming gowns, and optional infusion warming kits. It is intended for use by trained medical professionals to prevent hypothermia and maintain patient comfort in clinical settings such as operating rooms.
The manual covers system description, indications, safety symbols, contraindications, warnings, proper use and care, device start‑up and reset, control panel overview, installation on an IV pole, detailed operating instructions, troubleshooting, routine maintenance, cleaning, storage, technical support, warranty information, and full technical specifications. This manual is written in Chinese.
Covers: System Overview · Indications · Safety Symbols · Warnings and Contraindications · Proper Use and Care · Device Start‑up and Reset

TVYBIOTECH SINGLEC3 ELISA Kit Instruction Manual
The TVYBIOTECH SINGLEC3 ELISA kit uses a sandwich‑type assay to quantitatively detect Mouse SIGLEC3 protein in serum, plasma, urine or other biological fluids. The kit includes a precoated 96‑well plate, standards, detection reagents, substrate, stop solution and a detailed protocol.
The manual provides guidance on sample collection, reagent preparation, assay workflow, data analysis, and quality‑control criteria such as detection range, sensitivity, specificity, precision, repeatability, stability, and shelf‑life. Proper storage and safety precautions are also described.
Covers: Product Overview · Kit Components · Sample Collection and Storage · Reagent Preparation · Assay Procedure · Result Calculation
Latest Health Care manuals
Sanofi Frisium 10 mg Tablet Patient Information Leaflet
Product Leaflet 12 pages · 366 KB · ZHThis leaflet provides dosage, usage instructions, warnings, side effects and storage information for Frisium 10 mg tablets containing clobazam.
Instech Model 100 Syringe Infusion Pump Operations Manual
User Manual 51 pages · 951 KB · ENThe Instech Model 100 Syringe Infusion Pump Operations Manual provides setup, programming, safety, and maintenance instructions for the pump.
Bair Hugger 750 Temperature Management Device User Manual
User Manual 21 pages · 992 KB · ZHThe Bair Hugger 750 User Manual provides setup, operation, safety warnings, maintenance procedures, and technical specifications for the temperature…
TVYBIOTECH SINGLEC3 ELISA Kit Instruction Manual
User Manual 4 pages · 27 KB · ENInstruction manual for the TVYBIOTECH SINGLEC3 ELISA kit, covering components, sample handling, assay steps, and performance specifications.
ERLEADA Apalutamide Product Information Sheet
Product Leaflet 3 pages · 302 KB · ZHERLEADA (apalutamide) is an androgen‑receptor inhibitor for treating metastatic castration‑sensitive and non‑metastatic castration‑resistant prostate…
Jiangsu Shengbaoluo Lianbenbianzuo Solution Product Leaflet
Product Leaflet 1 pages · 93 KB · ZHLeaflet for Jiangsu Shengbaoluo Lianbenbianzuo Solution, a 25 ml topical antifungal medication.
Mitek VAPR II/VAPR 3 User Manual
User Manual 44 pages · 1.6 MB · ENThe Mitek VAPR II and VAPR 3 User Manual provides installation, operation, safety, maintenance, and troubleshooting instructions for the VAPR…
999 Gavirin Tablets Package Insert
Product Leaflet 4 pages · 131 KB · ZHThe 999 Gavirin Tablets package insert provides dosage, ingredients, indications, contraindications, side effects, storage, and manufacturer details.
NIDEK Le 1000 Patternless Edger Operator's Manual
User Manual 160 pages · 23.2 MB · ENThe NIDEK Le 1000 Patternless Edger Operator's Manual provides safety guidelines, setup, operation, maintenance, and disposal instructions.
National Reference Panel Hepatitis E Virus Nucleic Acid Detection Kit Reference Standard
Product Leaflet 3 pages · 137 KB · ZHReference panel for Hepatitis E virus nucleic‑acid detection kits, providing negative, positive, precision and detection‑limit samples.
Lifefeng DK803/DK805 Oral Swab DNA Extraction Product Selection Guide
Application Note 2 pages · 396 KB · ZHA guide from Lifefeng comparing DK803 and DK805 kits for oral swab DNA extraction, covering swab materials, performance, and sampling workflow.
CONTEC 08C Electronic Sphygmomanometer User Manual
User Manual 22 pages · 1.9 MB · ENThe CONTEC 08C electronic sphygmomanometer user manual provides safety precautions, operation steps, battery/adapter installation, settings, measurement…
BD Oral Syringes 1 ml, 3 ml, 5 ml, 10 ml Datasheet
Datasheet 4 pages · 362 KB · ENTechnical data sheet for BD Oral Syringes (1 ml, 3 ml, 5 ml, 10 ml) detailing materials, certifications, and specifications.
Chengdu Instrument Factory HS-4B Organ Temperature Controller User Manual
User Manual 7 pages · 460 KB · ZHThe manual explains setup, operation, and safety for the HS-4B ex‑vivo organ temperature controller.
Bio‑Rad Autoimmune Testing Product Catalog
Product Leaflet 80 pages · 4.7 MB · ENThe Bio‑Rad Autoimmune Testing Product Catalog lists the company’s autoimmune diagnostic systems, kits, and related instrumentation.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Application Note
How to use the product for one specific task, with worked examples.
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Quick Start Guide
The shortest path to a working setup, usually only a few pages.
Questions answered in Health Care manuals
How long does it take to charge the battery and how long will it run?
The battery can be fully recharged in no longer than 8 hours and will operate the pump for about 12 hours at 5 mL/hr with a 60 mL syringe.
From: Instech Model 100 Syringe Infusion Pump Operations Manual
Which syringe manufacturers are supported?
Supported syringes include Becton Dickinson (B‑D), Monoject, Terumo, B‑D Glass, and custom XXX syringes with the listed sizes.
From: Instech Model 100 Syringe Infusion Pump Operations Manual
What are the recommended environmental conditions for operating the Bair Hugger 750?
The device should be used in an ambient temperature of 15 °C to 25 °C, with relative humidity up to 80 % (maximum 31 °C), and at altitudes up to 2000 m.
From: Bair Hugger 750 Temperature Management Device User Manual
What types of samples can be tested with this kit?
The kit can be used with mouse serum, plasma, urine and other biological fluids, provided the samples are processed as described.
How should the kit be stored?
Store the kit at 4 °C for up to one week or at –20 °C for up to six months; avoid repeated freeze‑thaw cycles.
What is the recommended dosage of ERLEADA?
The recommended dosage is 240 mg taken orally once a day.
