ROTRONIC HTO-45 Humidity Temperature Probe Instruction Manual

This document is the operation manual of ROTRONIC HTO-45 humidity temperature probe. It introduces the product's features, operation methods, installation methods, maintenance methods, calibration methods and specific parameters.


ROTRONIC HTO-45 Humidity Temperature Probe Instruction Manual - cover page
Brand
Rotronic
Category
sensor
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
25 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
BCADA8DB309799CBE8BF3353277C7585

About this manual

The ROTRONIC HTO-45 is a combined humidity and temperature probe designed for use at normal room conditions. It utilizes a ROTRONIC HYGROMER CK60 humidity sensor and a BAV 99 diode temperature sensor to provide linearized voltage output signals suitable for data acquisition systems. The device operates on unregulated DC supply voltages ranging from 4.8 to 14.4 VDC or 15 to 24 VDC with a current consumption of 4 mA.

What's inside

  • Description
  • Operation
  • Installation
  • Maintenance
  • Calibration
  • Specifications

Specifications

Humidity Sensor TypeROTRONIC HYGROMER CK60
Temperature Sensor TypeBAV 99 diode
Recommended Operating Range (Humidity)25..90 %RH
Operating Temperature Range5..50 °C
Humidity Accuracy±3 %RH
Supply Voltage (4.8-14.4V)4.8 to 14.4 VDC
Supply Voltage (15-24V)15 to 24 VDC
Current Consumption4 mA

Frequently asked questions

How long must the probe be energized for a measurement?

Energizing of the probe is required for only 0.5 seconds during each measurement.

What are the output signal ranges?

The outputs provide 0...1.0 VDC corresponding to 0 to 100%RH and 0 to 100 °C.

What is the minimum load impedance for the output?

Do not connect a load with an impedance of less than 1000 Ω.

How often should calibration be verified?

For maximum accuracy, calibration may be verified every 6 to 12 months.

Download PDF (25 KB)