Bosch Rexroth CD01-PA Series ISO 15407-1 26 mm Valve Island Product Manual

This manual introduces the features and characteristics of the standard valve island series ISO 15407-1, 26 mm, series CD01-PA. It includes valve islands, valve groups and accessories, such as junction boxes, bridge connectors, etc.


Bosch Rexroth CD01-PA Series ISO 15407-1 26 mm Valve Island Product Manual - cover page
Brand
Rexroth
Category
Other
Document type
Product Leaflet
Language
Chinese
Pages
68
File format
PDF
File size
3.4 MB
Updated
30 September, 2023
Model
CD01-PA
MD5 checksum
D6F98973A212CD6331CB3D63E57B767E

About this manual

The Bosch Rexroth CD01-PA series is a valve island range built to ISO 15407-1 with a 26 mm size. The document lists valve island variants with single-plug wiring, C-type plug or M12 connections, multipin versions, and an optional ATEX version, along with directional valve and accessory pages.

The manual gives technical data for the series, including a maximum Qn of 1010 l/min, an operating pressure range of -0.95 to 16 bar, a control pressure range of 2 to 16 bar, ambient and media temperatures from -15°C to +50°C, and a compressed-air particle limit of max. 50 µm. It also covers sub-bases, end plates, pressure regulators, throttle valves, a power supply module, and pressure gauges. This manual is written in Chinese.

What's inside

  • Valve islands, series CD01-PA
  • Supplementary products, series CD01-PA
  • 2x 3/2 directional valves
  • 5/2 directional valves
  • 3-position 5-way directional valves
  • Electrical accessories
  • Single sub-base
  • Intermediate and end plates
  • Pressure regulators
  • Throttle valves

Specifications

Standard and sizeISO 15407-1, 26 mm
Qn max.1010 l/min
Operating pressure range-0.95 bar / 16 bar
Control pressure, min./max.2 bar / 16 bar
Ambient temperature, min./max.-15°C / +50°C
Media temperature, min./max.-15°C / +50°C
MediumCompressed air
Particle size, max.50 µm
Oil content in compressed air0 mg/m³ - 1 mg/m³
Standardized electrical connectionEN 175301-803, C-type
Operating voltage DC24 V DC
Operating voltage AC230 V, 110 V
ATEXII 3G Eex nA IIB T4 X; 0°C <= Ta <= 50°C
Valve positions, multipin version12

Frequently asked questions

What standard and size does the CD01-PA valve island series use?

It uses ISO 15407-1 with a 26 mm size.

What is the operating pressure range of the CD01-PA valve island?

The operating pressure range is -0.95 bar to 16 bar.

What electrical connection options are listed for the CD01-PA valve island?

The listed electronic connections include a C-type plug and an M12 connector.

What is the maximum particle size allowed in the compressed air?

The maximum particle size is 50 µm.

Download PDF (3.4 MB)