Morningstar ProStar Troubleshooting Guide

This is a document about ProStar troubleshooting guide. It introduces troubleshooting methods for ProStar overcharge, ProStar does not charge battery, LVD does not work, battery type selection does not work, controller goes into LVD when battery voltage is much greater than 11.6V, meter does not work, controller does not start.


Morningstar ProStar Troubleshooting Guide - cover page
Brand
Morningstar
Category
Other Electronics
Document type
Service Manual
Language
English
Pages
14
File format
PDF
File size
465 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
CD1ED51EB9044C743AEC3F33CA86D13A

About this manual

This document serves as a troubleshooting guide for the Morningstar ProStar charge controller, published by Morningstar Corporation in April 2000. It assumes basic circuit knowledge and safety precautions when working with live circuits in solar energy systems. The guide outlines necessary equipment, including multimeters, adjustable power supplies, and specific tools for soldering and component replacement.

What's inside

  • ProStar Overcharges battery
  • ProStar does not charge battery
  • LVD does not work
  • Load does not turn on
  • Battery Type select does not work
  • Controller goes into LVD
  • Meter does not work
  • Controller does not start
  • ProStar MOSFET Replacement
  • ProStar Test Point Summary

Frequently asked questions

What equipment is necessary to troubleshoot and repair the ProStar controllers?

Required equipment includes a multimeter, an adjustable power supply capable of supplying 2A at 15V, a small lead acid battery (7aHr), a load of approximately 2A, screwdrivers, a soldering iron, wire cutters, and needle nose pliers.

How can I determine if the Input MOSFETs are damaged?

If the voltage at TP10 is greater than 10V when the battery voltage is measured at the PV input terminals, the input MOSFETs are damaged and need to be replaced.

What should I do if the ProStar meter shows bad values or garbage?

If the meter shows garbage or erratic readings, the meter driver chip is bad and requires the meter to be replaced with a working meter board.

Download PDF (465 KB)