ABB Drives 3AFE 6873 5190 00522808 Capacitor Reforming Inspection Instruction

This instruction introduces the methods for reforming the DC link capacitors of ABB drives ACS50, ACS55, ACS150, ACS310, ACS350, ACS355, ACS550, ACH550 and R1-R4 OINT-/SINT-boards.


ABB Drives 3AFE 6873 5190 00522808 Capacitor Reforming Inspection Instruction - cover page
Brand
ABB
Category
Industrial Robot
Document type
Service Manual
Language
English
Pages
5
File format
PDF
File size
79 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
3AE428503575DEE1D4CE42CB96665C56

About this manual

This document provides instructions for inspecting the age of ABB Drives to determine if DC link capacitors require reforming. If a drive has been non-operational for more than one year, the capacitors must be reformed to prevent damage upon startup. The guide details how to check the manufacturing date from the serial number and specifies the required reforming time based on storage duration.

What's inside

  • Reforming
  • How to check the drive's age
  • Reforming time
  • Drives stocked for less than 2 years
  • Drives stocked for 2 years and over
  • Method 2A
  • Method 2B
  • Replacement
  • Reforming instructions for R1-R4 OINT- and SINT-boards

Frequently asked questions

When must drive capacitors be reformed?

Capacitors need to be reformed if the drive has been non-operational for more than one year.

How often is it recommended to reform capacitors?

It is recommended to reform the capacitors once a year.

What happens if capacitors are not reformed?

Without reforming, capacitors may be damaged when the drive starts to operate.