Hayward Aqua Rite Electronic Chlorine Generator Operation and Installation Manual

This manual describes the basic maintenance requirements of electronic chlorine generators


Hayward Aqua Rite Electronic Chlorine Generator Operation and Installation Manual - cover page
Brand
Hayward
Category
Other
Document type
User Manual
Language
English
Pages
10
File format
PDF
File size
190 KB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
BC7FAF6447470CEED62354DB7EC5037F

About this manual

The Hayward Aqua Rite is an electronic chlorine generator designed for swimming pools, spas, and hot tubs. It operates by generating chlorine from salt dissolved in the water, maintaining a desired free chlorine level between 1.0 and 3.0 ppm. The device includes features for monitoring water chemistry, such as pH, alkalinity, salt levels, and stabilizer concentrations, and provides LED indicators for status and fault conditions like low salt, high salt, or cell inspection needs.

What's inside

  • Water Chemistry
  • Operation
  • Maintenance
  • Mounting
  • Wiring
  • Troubleshooting
  • Warranty

Specifications

Free Chlorine Range1.0-3.0 ppm
pH Range7.2-7.8
Alkalinity Range80-120 ppm
Salt Range2700 - 3400 ppm
Stabilizer Range60 - 80 ppm
Calcium Range200 - 400 ppm

Frequently asked questions

What is the ideal free chlorine level for the pool?

The desired output should be adjusted to maintain a free chlorine level between 1.0 and 3.0 ppm.

What should be done if the "Inspect Cell" LED is flashing?

Inspect and clean the cell according to the directions in the manual, then press the diagnostic button for 3 seconds to stop the flashing.

What causes the "-Pcb-" display with all LEDs illuminated?

This indicates a possible Printed Circuit Board fault, and service should be called.