ARRICAM Accessories Quick Guide provides a short introduction to the ARRICAM Accessories.
The document serves as a quick introduction to various ARRICAM accessories, covering tools, software, safety guidelines, and an overview of components. It references related guides such as the System Guide and User's Guide, emphasizing that users must consult the latter before operating equipment.
Detailed sections describe specific accessories including the Manual Control Box (MCB) for adjusting frame rate and shutter angle, the Speed Control Box (SCB) for programmable ramps and synchronization, and various data display units. The guide also outlines necessary tools for assembly and lists critical safety specifications for operation.
| Software version described | ARRICAM System with Software Packet 03E |
|---|---|
| Minimum frame rate (MCB) | 1 fps |
| Maximum forward frame rate (Studio MCB) | 60 fps |
| Maximum forward frame rate (Lite MCB) | 40 fps |
| Minimum recommended shutter angle | 11.2° |
If the SCB is connected, its COMPENSATION switch must be set to OFF when using the Manual Control Box to adjust the shutter opening.
You must use the 1.5 mm metric hex wrench found on one end of the ARRICAM Ground Glass Tool.
An 8-10mm (5/16") flathead long shaft screwdriver is required for this task.
The maximum forward frame rate is 40 fps.