STMicroelectronics AN3040 4 x 18 W T8 Ballast Application Note

This application note describes a demonstration board able to drive a 4 x 18 W linear T8 fluorescent tubes. The ballast is controlled by the new L6585DE IC that integrates the PFC and half-bridge control circuits, relevant drivers, and the circuitry that manages all the operating phases (preheating, ignition and run mode) of the lamp. Protections against failures such as lamp disconnection, anti-capacitive mode and PFC overvoltage are guaranteed and obtained with a minimum number of external components. In addition to the description of the circuit and design criteria, this document provides a short overview of the ballast performances.


STMicroelectronics AN3040 4 x 18 W T8 Ballast Application Note - cover page
Brand
STMicroelectronics
Document type
Application Note
Language
English
Pages
27
File format
PDF
File size
696 KB
Published
06 August, 2012
Updated
29 September, 2023
MD5 checksum
01C466FBE776100C06DDECE5D87C2225

About this manual

The document details an electronic ballast design capable of driving four 18 W T8 linear fluorescent tubes. The circuit is controlled by the L6585DE integrated circuit, which combines Power Factor Correction (PFC) and half-bridge control circuits along with necessary drivers. This solution manages all operating phases including preheating, ignition, and run mode while providing protections against lamp disconnection and overvoltage.

What's inside

  • Basis of half-bridge inverter topology
  • Main characteristic
  • L6585DE pin-by-pin biasing circuitry
  • PFC power section design
  • Design of the half-bridge inverter
  • Experimental results
  • Automatic restart circuit for lamp replacement

Specifications

Input voltage range85 to 265 V RMS
Line frequency50/60 Hz
Tube lamp number4
Tube lamp typeT8
Power per tube18 W
Power factor≥0.9
Total harmonic distortion≤10%
Efficiency≈90%

Frequently asked questions

What IC controls the ballast described in this note?

The ballast is controlled by the new L6585DE IC that integrates the PFC and half-bridge control circuits.

What are the operating phases managed by the circuit?

The circuit manages all operating phases including preheating, ignition, and run mode.

What protections are guaranteed by this design?

Protections against failures such as lamp disconnection, anti-capacitive mode, and PFC overvoltage are guaranteed.