STMicroelectronics AN3353 Application Note IEC 61000-4-2 Testing

This document explains how STMicroelectronics protection devices are tested according to the IEC 61000-4-2 standard, which is used to test electrostatic discharge immunity. The document also answers frequently asked questions and describes the features and characteristics of the products.


STMicroelectronics AN3353 Application Note IEC 61000-4-2 Testing - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Application Note
Language
English
Pages
9
File format
PDF
File size
172 KB
Published
06 August, 2012
Updated
29 September, 2023
MD5 checksum
6EAC69A6A1813A5E260F9EE4EE1301FA

About this manual

This document is an application note addressed to technical engineers and designers, detailing how STMicroelectronics protection devices are tested against the IEC 61000-4-2 standard. It clarifies that while contact discharge is the preferred test method, air discharge is used for insulating surfaces, with specified levels typically reaching 8 kV for contact and 15 kV for air discharge.

The note describes the specific test benches adapted by STMicroelectronics for standalone protection devices, including the use of dedicated PCBs with SMA plugs for clamping voltage measurements. It outlines procedures for both air and contact discharge tests using rounded or sharp ESD gun tips, respectively, and details the equipment used to measure clamping voltage waveforms in contact mode at +8 kV.

What's inside

  • Introduction
  • Market environment
  • Contact discharge or air discharge?
  • Test benches
  • STMicroelectronics test bench
  • Air discharge test
  • Contact discharge test
  • Clamping voltage measurement

Frequently asked questions

What is the preferred ESD testing method according to IEC 61000-4-2?

According to the standard, contact discharge is the preferred test method.

What are the specified ESD levels for STMicroelectronics protection devices?

The specified levels are most of the time 8 kV for contact discharge and 15 kV for air discharge.

At what voltage is the clamping voltage measured?

The clamping voltage measurement is done in contact mode at +8 kV.