MP FILTRI FMP 038 Filter Technical Data Sheet

The document describes the features and characteristics of a certain brand and model of product.


MP FILTRI FMP 038 Filter Technical Data Sheet - cover page
Brand
MP
Document type
Datasheet
Language
English
Pages
1
File format
PDF
File size
27 KB
Published
10 July, 2012
Updated
29 September, 2023
Model
FMP 038
MD5 checksum
7DCE0861579C40ECA9A3979CE0CE94D8

About this manual

This document provides technical specifications for the MP FILTRI FMP 038 filter element. It lists recommended maximum flow rates in liters per minute (l/min) corresponding to different series types (AOS, AO6, A10, etc.) under specific test conditions.

The data assumes a pressure drop of complete filter equal to 1.5 bar and an oil kinematic viscosity of 30 mm2/s (cSt). The document also specifies the density used for testing as 0.86 kg/dm³.

What's inside

  • Recommended maximum flow rate
  • Pressure drop
  • Oil kinematic viscosity
  • Density
  • Threaded Connections
  • Indicator and bypass valve positions
  • Clogging indicator
  • Bypass valve standard position
  • Plug T2- Ch. 30
  • Side B Length mm

Specifications

Recommended maximum flow rate (Series AOS 20)6 l/min
Pressure drop of complete filterAp 1.5 bar
Oil kinematic viscosity (test condition)30 mm2/s (cSt)
Density (test condition)0.86 kg/dm³
Connections of filter under testG 1/2"

Frequently asked questions

What is the recommended maximum flow rate for the FMP 038 filter?

The recommended maximum flow rate is 1.5 bar when the pressure drop of the complete filter equals this value.

What oil kinematic viscosity is required for the FMP 038 filter?

The filter requires an oil kinematic viscosity of 30 mm2/s (cSt).