Agilent LC/MSD TOF Effect of Resolution and Mass Accuracy Technical Overview

This document introduces the features and advantages of Agilent LC/MSD TOF mass spectrometer, including high mass resolution and high mass accuracy, as well as atmospheric pressure ionization sources. It can confirm the empirical formulas of small molecule organic compounds and identify unknown compounds.


Agilent LC/MSD TOF Effect of Resolution and Mass Accuracy Technical Overview - cover page
Brand
Agilent
Category
Other Electronics
Document type
Other
Language
English
Pages
6
File format
PDF
File size
475 KB
Published
05 July, 2012
Updated
01 October, 2023
MD5 checksum
A7C0AD7979033C863AE805CED4F3A452

About this manual

This document explains the theory and concepts behind mass resolution and mass accuracy and how they affect the ability to unambiguously confirm empirical formulas of small molecule organic compounds or identify unknowns. It highlights that both very good mass resolution and mass accuracy are required to positively distinguish between compounds with the same nominal mass.

The text details the design elements of the Agilent LC/MSD TOF that enhance its resolving power and mass accuracy. These include a beam shaper, one-dimensional harp grids, and an analog-to-digital acquisition system with an automated calibrant delivery system for continuous mass correction.

What's inside

  • Introduction
  • The Effect of Mass Resolution
  • Mass Resolution and Resolving Power
  • Average Mass
  • Monoisotopic Mass
  • Resolving Compounds with Identical Nominal Masses
  • Mass Accuracy
  • Accurate Mass Measurements
  • Design for Mass Accuracy

Specifications

Resolving Power at 100 u2,000
Resolving Power at 1000 u20,000
Mass Accuracy at 120 uapproximately 4 ppm

Frequently asked questions

How does the Agilent LC/MSD TOF improve mass accuracy?

It uses an analog-to-digital acquisition system combined with an automated calibrant delivery system and a second nebulizer to allow continuous introduction of a reference mass compound for mass correction.

What is the primary use of the Agilent LC/MSD TOF mass spectrometer?

It is designed for empirical formula confirmation of small molecule organic compounds.

What mass accuracy does the Agilent LC/MSD TOF have at 120 u?

The instrument has a mass accuracy of approximately 4 ppm at 120 u.

How does the instrument achieve continuous mass correction without contamination?

It uses an analog-to-digital acquisition system combined with an automated calibrant delivery system and a second nebulizer.

Download PDF (475 KB)

More Agilent Manuals