Agilent VICI Valve Control Software for EZChrom Elite CDS User Manual

Agilent Technologies' EZChrom Elite CDS and Agilent OL Operating System for the Laboratory are software systems well known for their comprehensive instrument control. In addition to software control of many commercial Gas Chromatographs, autosamplers and HPLC instruments, EZChrom Elite and Agilent OL can also control two position and Multi- position Microelectric Actuated valves from VICI AG (Valco Instruments Co, Inc) with optional instrument control software. This capability allows VICI valves to be integrated into an HPLC or GC instrument system for additional sampling control. The VICI Valve instrument control software option allows the software method to specify which stream position to use before the chromatographic run is started. Used in this way, the VICI Valve functions as a sampling device. By setting a delay between selecting a stream and staring a run, it is possible to optimize the cleaning of the sample loop of the injection valve. In addition to its use as a sampling device, the VICI valve may be used in a standard stream switching role. By entering commands into an EZChrom or Agilent OL method timed event table, multiple valves can be switched during the chromatographic analysis.


Agilent VICI Valve Control Software for EZChrom Elite CDS User Manual - cover page
Brand
Agilent
Category
Other Electronics
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
245 KB
Published
04 July, 2012
Updated
30 September, 2023
MD5 checksum
D6BF6B5C5556722EDDEDB6619CC6C696

About this manual

The Agilent VICI Valve Control Software for EZChrom Elite CDS enables the control of VICI AG (Valco Instruments Co, Inc) microelectric actuated valves. This software option allows the EZChrom Flite and Agilent OL Operating System to specify stream positions before a chromatographic run starts, functioning as a sampling device. It also supports standard stream switching roles where multiple valves can be switched during analysis via timed event tables.

What's inside

  • Key Benefits
  • Practical Usage
  • Other Possible Applications
  • Specifications
  • VICI Valves Supported
  • Communications
  • Restrictions

Specifications

Supported ValvesEMHA 2-position valves, EMHCA Multi-Position, EMTCO Multi-Position
Delay after switching0.0 to 10.0 minutes
Communications InterfaceRS-232 (1200 to 38400 Baud)
Compatible SystemsOver 300 different LC and GC systems

Frequently asked questions

What is the primary function of the VICI Valve control software?

It allows the software method to specify which stream position to use before the chromatographic run is started, functioning as a sampling device.

Can the valve switching be programmed during an acquisition run?

Yes, by entering commands into an EZChrom or Agilent OL method timed event table, multiple valves can be switched during the chromatographic analysis.

Is the software configurable in combination with a standard sampler?

No, the software has restrictions and is not configurable in combination with a standard sampler.