Agilent G6410 Rapid Sensitive Analysis Method for Sudan Reds in Curry Chili Powder Using LC/MS/MS Application Note

A method was developed using the Agilent G6410 Triple Quadrupole LC/MS for Sudan Reds in different matrices, including curry powder, red pepper powder, and chili sources. The analytical performance of the method was evaluated for four different matrices and the results show little or no matrix effects. Linearity of response over three orders of magnitude was demonstrated (r > 0.99). In addition, good reproducibility of the two required product ion ratios was obtained to meet the EU identification points needed for confirmation. A Rapid and Sensitive Analysis Method for Sudan Reds in Curry and Chili Powder Using LC/MS/MS Application Introduction


Agilent G6410 Rapid Sensitive Analysis Method for Sudan Reds in Curry Chili Powder Using LC/MS/MS Application Note - cover page
Brand
Agilent
Document type
Application Note
Language
English
Pages
10
File format
PDF
File size
226 KB
Published
12 June, 2012
Updated
28 September, 2023
Model
G6410
MD5 checksum
106BA9A18A0F84789B8FF04713296C7F

About this manual

The document presents an analytical method developed for detecting Sudan Red I, II, III, IV, and Para Red in various matrices such as curry powder, red pepper powder, and Worcestershire sauce. The method utilizes the Agilent G6410 Triple Quadrupole LC/MS system with electrospray ionization (ESI) operated in positive mode to meet EU testing requirements for these prohibited food colorants.

The procedure details sample preparation techniques involving extraction with ethyl acetate, ultrasonication, and filtration. It specifies the chromatographic conditions using a ZORBAX XDB C18 column and provides specific Mass Spectrometry settings, including MRM transitions, fragmentor voltages, and collision energies optimized for each analyte to ensure high sensitivity and selectivity.

What's inside

  • Introduction
  • Reagents and Materials
  • Sample Preparation
  • LC/MS/MS Conditions
  • Optimization of MS Condition
  • Dye Structures
  • Results and Discussion

Specifications

ColumnZORBAX XDB C18 2.1 mm x 100 mm, 1.8 ym
Flow rate0.4 mL/min
Drying gas temp.350°C
Veap voltage3500 V

Frequently asked questions

Which Sudan Red dyes does this method analyze?

The method analyzes Para Red, Sudan Red I, Sudan Red II, Sudan Red III, and Sudan Red IV.

What is the detection limit demonstrated for this method?

The methodology demonstrates sensitivity with a spike of chili powder at 1 ppb.

What type of ionization source is used?

The analysis uses an electrospray ionization (ESI) source operated in positive mode.

Download PDF (226 KB)