The EP/VP series of RFI filters are designed to reduce conducted noise to acceptable limits for equipment that must comply with the requirements of CISPR in Europe and the FCC specifications in the USA.
The document describes the EP/VP series of Radio Frequency Interference (RFI) power line filters developed to reduce conducted noise in equipment complying with CISPR European and FCC USA specifications. These models are particularly suited for stringent emissions requirements, such as CISPR 22 A-level and FCC Part 15J Class B, with EP models meeting very low leakage current requirements.
| Operating frequency | 50/60 Hz |
|---|---|
| Rated voltage | 120/250 VAC |
| Hipot rating (line-to-ground) | 2250 VDC |
| Maximum leakage current @ 120VAC | 73 mA (VP Models) |
These filters are designed to reduce conducted noise to acceptable limits for equipment that must comply with CISPR and FCC specifications.
Line Cord No. GA400 includes a 712 foot, 3-conductor line cord.