Analog Devices AD594/AD595 Monolithic Thermocouple Amplifiers Specification Sheet

The AD594/AD595 is an integrated temperature sensor with cold junction compensation, which can be used with Type J, Type K and Type T thermocouples. It combines an ice point reference with a precalibrated amplifier to produce a high level (10 mV/°C) output directly from a thermocouple signal. Pin-strapping options allow it to be used as a linear amplifier-compensator or as a switched output setpoint controller using either fixed or remote setpoint control. It can be used to amplify its compensation voltage directly, thereby converting it to a stand-alone Celsius transducer with a low impedance voltage output. The AD594/AD595 includes a thermocouple failure alarm that indicates if one or both thermocouple leads become open. The alarm output has a flexible format which includes TTL driver output, integrated circuit driver output and passive decoder output.


Analog Devices AD594/AD595 Monolithic Thermocouple Amplifiers Specification Sheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
8
File format
PDF
File size
137 KB
Published
04 June, 2012
Updated
30 September, 2023
Models
AD594, AD595
MD5 checksum
26D2ABBABBAC6DB6FB163606DC340D1F

About this manual

The AD594 and AD595 are monolithic thermocouple amplifiers that integrate cold‑junction compensation, high‑gain amplification, and a low‑impedance voltage output (10 mV/°C). They are laser‑trimmed for Type J (AD594) or Type K (AD595) thermocouples and can also be configured for other thermocouple types through external recalibration.

The devices operate from a wide supply range, support both single‑supply (+5 V) and dual‑supply configurations, and include a thermocouple failure alarm. Key specifications such as power‑supply range, quiescent current, calibration error, and operating temperature range are listed in the specification tables.

What's inside

  • Features
  • Product Description
  • Product Highlights
  • Specifications
  • Thermocouple Type J
  • Thermocouple Type K
  • Single and Dual Supply Connections
  • Thermocouple Connections
  • Functional Description
  • Recalibration Principles

Specifications

Power Consumption<1 mW typical
Operating Temperature Range–55 °C to +125 °C
Calibration Error (typical at +25 °C)1.63 °C

Frequently asked questions

How does the AD594/AD595 provide cold‑junction compensation?

The device includes an internal ice‑point reference and a precalibrated amplifier that together provide cold‑junction compensation.

Can the AD594/AD595 be powered from a single supply?

Yes, it can operate from a single +5 V supply.