This one-page technical information sheet from April 2001 covers the QUICKTRONIC MULTIWATT electronic control gear (ECG) with the reference QT-M 2x26-32/230-240 S, intended for compact, tubular and circular fluorescent lamps. Listed product features include suitability for frequent on/off switching and for emergency installations according to VDE 0108, use in luminaires of protection class I and II, automatic end of lamp life protection and automatic lamp restart after a lamp change.
The technical data section gives lamp combinations with HF lamp wattage, system wattage, line current and luminous flux at 25 °C, together with supply voltage, voltage ranges, frequencies, interference standards, power factor, temperature limits, dimensions, mounting hole distance, weight and approval marks. The sheet also notes that various lamp wattages can be operated simultaneously on the ECG unless the total is 64 W.
| Supply voltage | 230/240 V |
|---|---|
| Voltage range (AC) | 198 V - 254 V |
| Voltage range (DC) | 176 V - 254 V |
| Rated frequency | 0/50-60 Hz |
| Operating frequency | approx. 45 kHz |
| Preheating time | < 1 sec. |
| Power factor | 0.97 (capacitive) |
| Temperature range | -20 °C to +50 °C |
| Case temperature | max. +70 °C |
| Dimensions (l x w x h) | K3, 123 x 79 x 33 mm |
| Distance between mounting holes | 129.5 mm |
| Weight | 240 g |
The table lists two-lamp operation of DULUX D/E, T/E, L and F lamps as well as L 18 W, FC 22 W and FQ 24 W lamps, plus a 1x FC 22 W + 40 W combination.
It is rated for 230/240 V supply, with a voltage range of 198 V to 254 V AC and 176 V to 254 V DC.
Yes, various lamp wattages can be operated simultaneously on the ECG unless the total is 64 W.
Yes, it is described as suitable for emergency installations according to VDE 0108.