This manual introduces the basic use of Speedrite battery energizer, including installation, operation, battery selection and management, building a permanent electric fence, temporary electric fencing, safety considerations, frequently asked questions and troubleshooting, maintenance and product specifications.
This manual covers the Speedrite Delta series of battery‑powered electric fence energizers. It explains safety considerations, installation options (solar or battery‑only), wiring diagrams, and how to set the Power Output and Pulse Speed switches for optimal performance.
Additional sections describe battery selection and management, charging procedures, troubleshooting, and detailed product specifications for the Delta 1B, 2B, and 3B models. The guide is intended for farmers and qualified installers who need reliable animal control.
| Current required (Full Power‑Fast Pulse) – Delta 1B | 70 mA |
|---|---|
| Minimum battery capacity – Delta 1B (solar) | 60 Ah |
| Current required (Full Power‑Fast Pulse) – Delta 2B | 140 mA |
| Current required (Full Power‑Fast Pulse) – Delta 3B | 340 mA |
Do not connect to mains‑operated equipment, switch the energizer off before installation, and ensure the installation complies with local safety regulations.
The lights show the battery’s charge level—green for optimal, yellow for medium, red for low, and flashing patterns for faults.
A minimum of 60 Ah 12 V lead‑acid battery is recommended for a Delta 2B solar system.