Microchip MCP131X/2X Voltage Supervisor Datasheet

MCP131X/2X is a series of voltage supervisor devices introduced by Microchip Technology Inc., designed to keep a microcontroller in Reset until the system voltage has reached and stabilized at the proper level for reliable system operation. This family of devices also offers a Watchdog Timer to monitor system operation and a Manual Reset input.


Microchip MCP131X/2X Voltage Supervisor Datasheet - cover page
Brand
MICROCHIP
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
44
File format
PDF
File size
1.2 MB
Published
08 May, 2012
Updated
28 September, 2023
Models
MCP131X, MCP2X
MD5 checksum
06E1D5B7315AD73F6CB59149B3F96F29

About this manual

The MCP131X/2X family of voltage supervisor devices monitors system voltage and provides a reset signal until the voltage reaches a stable level. The devices also include a watchdog timer and manual reset input, with selectable trip points and reset‑delay options.

The datasheet lists detailed electrical specifications, package options, and timing parameters for each part number (MCP1316, MCP1317, MCP1318, MCP1319, MCP1320‑22). It also describes reset‑output configurations, temperature ranges, and code‑protection features.

What's inside

  • Features
  • Package Types
  • Device Features
  • Electrical Specifications
  • DC Characteristics
  • Reset Output Options
  • Trip Point Options
  • Timing Parameters
  • Code Protection

Specifications

Operating Voltage Range1.0 V to 5.5 V
Temperature Range-40°C to +125°C
Supply Current (typical)5 µA
Reset Output OptionsPush‑Pull (active‑high or active‑low) and Open‑Drain

Frequently asked questions

What is the operating voltage range of the MCP131X/2X devices?

The devices operate from 1.0 V up to 5.5 V.

What reset output types are available?

Both push‑pull (active‑high or active‑low) and open‑drain (with internal or external pull‑up) outputs are supported.

What reset‑delay time options can be selected?

The reset‑delay can be set to 1.4 ms, 30 ms, 200 ms, or 1.6 s (typical).

What temperature range can the devices operate in?

They are rated for operation from –40 °C to +125 °C.