Analog Devices AD7414/AD7415 Datasheet Rev F

This document is the introduction manual of AD7414/AD7415 products of ADI company, which introduces the product characteristics, including 10-bit temperature-to-digital converter, temperature range, typical accuracy, SMBus/I2C® compatible serial interface, 3μA power-down current, temperature conversion time, space-saving 6-lead (AD7414) and 5-lead (AD7415) SOT-23 packages etc.


Analog Devices AD7414/AD7415 Datasheet Rev F - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
20
File format
PDF
File size
362 KB
Published
05 May, 2012
Updated
30 September, 2023
Model
AD7415
MD5 checksum
51ADBE627C252750D91422D4BF6B8264

About this manual

The AD7414 and AD7415 are 10‑bit digital temperature sensors offered in compact 5‑lead and 6‑lead SOT‑23 packages. They provide a SMBus/I²C‑compatible two‑wire serial interface, selectable I²C addresses, and an optional ALERT output for over‑temperature monitoring. Designed for low power consumption (3 pA power‑down) and a supply range of 2.7 V to 5.5 V, they are suited for applications such as hard‑disk drives, PCs, test equipment, and domestic appliances.

Key specifications include a temperature range of –40 °C to +125 °C, typical accuracy of ±0.5 °C at 40 °C, 10‑bit resolution (0.25 °C per LSB), and a conversion time of about 25 µs. The devices support up to eight I²C addresses for the AD7414 and six for the AD7415, and feature programmable high‑temperature limits and ALERT polarity.

What's inside

  • Specifications
  • Absolute Maximum Ratings
  • Pin Configurations and Function Descriptions
  • Theory of Operation
  • Circuit Information
  • Functional Descriptions
  • Measurement Technique
  • Temperature Data Format
  • Serial Interface
  • Power Supplies

Specifications

Temperature range-40 °C to +125 °C
Typical accuracy at 40 °C±0.5 °C
Resolution10 bits (0.25 °C per LSB)
Supply voltage2.7 V to 5.5 V
Power‑down current3 pA
Temperature conversion time25 µs typ
Update rate (one‑shot period)800 ms typ
I²C address options (AD7414)8 addresses
I²C address options (AD7415)6 addresses
Input high voltage24 V min
Output low voltage0.4 V max

Frequently asked questions

What temperature range does the AD7414/AD7415 cover?

The sensors operate from –40 °C up to +125 °C.

What is the typical accuracy of the AD7414/AD7415 at 40 °C?

Typical accuracy is ±0.5 °C at a temperature of 40 °C.

How many I²C addresses can the AD7414 provide?

The AD7414 can be configured for up to eight different I²C addresses.

What is the supply voltage range for these sensors?

They operate from 2.7 V to 5.5 V.