Fluke 355/353 Clamp Meter Datasheet

Fluke 355/353 is a clamp meter designed for high current measurement applications. It provides high accuracy and wide measurement range, up to 2000 A ac + dc true-rms, 1400 A ac and 2000 A dc. It is suitable for utilities, electrical contractors and industrial service technicians.


Fluke 355/353 Clamp Meter Datasheet - cover page
Brand
Fluke
Category
Other
Document type
Datasheet
Language
English
Pages
3
File format
PDF
File size
476 KB
Published
04 May, 2012
Updated
30 September, 2023
MD5 checksum
611E3B01040887E59FFE4F3BDCF0A5F4

About this manual

The Fluke 355 and 353 clamp meters provide true‑RMS current measurement up to 2000 A AC + DC with an extra‑wide 58 mm jaw, making them suitable for industrial and utility applications. They also measure voltage, resistance, continuity and frequency, offering a versatile tool for electricians and service technicians.

Key specifications include CAT IV 600 V / CAT III 1000 V safety ratings, a backlit display, MIN/MAX/AVG functions, and a battery life of about 100 hours with the backlight off. The meters are powered by six 1.5 V AA batteries and weigh only 0.814 kg, fitting comfortably in the hand for field use.

What's inside

  • Technical Data
  • Specifications
  • Current measurement
  • Voltage measurement
  • Ohms measurement
  • General specifications
  • Battery
  • Safety rating
  • Environmental specifications

Specifications

Maximum current measurement2000 A AC + DC true‑RMS (1400 A AC RMS)
Jaw size58 mm (2.28 in)
Battery typeSix 1.5 V AA (NEDA 15 A or IEC LR6)
Battery life (backlight off)≈100 hours
Weight0.814 kg (1.8 lb)
Safety ratingCAT IV 600 V, CAT III 1000 V

Frequently asked questions

What is the maximum current the Fluke 355/353 can measure?

It can measure up to 2000 A AC + DC true‑RMS (and 1400 A AC RMS).

What safety ratings does the clamp meter have?

The meter is rated CAT IV 600 V and CAT III 1000 V for added user protection.

How large is the jaw on the Fluke 355/353?

The jaw size is 58 mm (2.28 in).

How long does the battery last with typical use?

The battery provides about 100 hours of operation when the backlight is off.