3M 8822 Respirator Data Sheet

This document describes the standards and performance tests of the 8822 respirator, as well as the precautions for use. The 8822 respirator is a lightweight, effective, comfortable, and hygienic respirator for dust and mist protection.


3M 8822 Respirator Data Sheet - cover page
Brand
3M
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
158 KB
Published
09 April, 2012
Updated
29 September, 2023
MD5 checksum
84B4A1A03694C2F9490558D81B3B4E1A

About this manual

The 3M 8822 respirator offers lightweight, comfortable protection against dusts and mists. Its convex shape, twin‑strap design, foam nose seal and steel nose clip provide a reliable face seal, while a unique valve and collapse‑resistant shell ensure durability in hot and humid conditions.

The respirator meets European standards EN149:2001 FFP2, is CE‑marked, and is suitable for applications such as metal manufacturing, pharmaceuticals, agriculture, food processing, and construction. The sheet also includes fitting instructions, safety warnings, and contact details for 3M health‑and‑safety support.

What's inside

  • Main Features
  • Standards
  • Applications
  • Approvals
  • Materials
  • Weight
  • Performance Tests
  • Warnings
  • Fitting Instructions

Specifications

Weight13 g
Assigned Protection Factor10 (Nominal Protection Factor 12)
Strap materialNatural Rubber
Nose‑clip materialSteel
Filter materialPolypropylene
Nose foam materialPolyurethane
Valve materialPolypropylene
Standard complianceEN149:2001 FFP2, CE‑marked

Frequently asked questions

What protection factor does the 3M 8822 respirator provide?

It offers an Assigned Protection Factor of 10 (Nominal Protection Factor of 12).

What materials are used in the 3M 8822 respirator?

The straps are natural rubber, the nose‑clip is steel, the filter and valve are polypropylene, and the nose foam is polyurethane.

Which standards does the 3M 8822 respirator meet?

It meets the European Standard EN149:2001 FFP2 and is CE‑marked.

How do you check the seal of the respirator before use?

Cover the front, inhale sharply to feel negative pressure, and adjust the strap or position if any leakage is detected.

Download PDF (158 KB)