This short form user's manual provides the basic information needed for installing and commissioning the drive.
The short form user’s manual gives the essential information needed to install and commission the ABB ACS310 drive. It references the full ACS310 user manual for detailed planning, program features, fieldbus, signals, parameters, fault tracing, maintenance, and dimension drawings.
The document covers safety precautions, hardware description, mechanical and electrical installation, start‑up and I/O control, technical data, and power‑cable sizing. It also lists related manuals, product‑service contacts, and how to access the ABB document library online.
| Input voltage range (single‑phase) | 200–240 V AC |
|---|---|
| Power rating (kW) for frame R0 | 0.37 kW |
| Overload capacity | 10% for one minute every ten minutes |
No, the drive is not field‑repairable; a qualified service center must replace it.