Mälarenergi replaced resistors and slip-ring motors with four ACS 1000 variable speed drive systems, which improved the efficiency of the power and district heating plant. The production of electrical energy was increased by about 35 GWh per year.


ABB ACS1000 Case Note - cover page
Brand
ABB
Category
Other Electronics
Document type
Application Note
Language
English
Pages
4
File format
PDF
File size
311 KB
Published
22 March, 2012
Updated
29 September, 2023
Model
ACS1000
MD5 checksum
779C7892380D28AE015C28A66394EABC

About this manual

This case note explains how Malarenergi AB replaced resistors and slip‑ring motors with four ABB ACS1000 variable speed drives, each rated at 1765 kW, to control district‑heating pumps. The upgrade reduced heat losses, increased electricity production by about 35 GWh per year, and lowered CO₂ emissions.

The document also details the technical data of the ACS1000 drives, the automatic differential‑pressure control achieved, and the overall benefits such as higher plant efficiency, reduced maintenance costs, and improved customer satisfaction.

What's inside

  • Background
  • Challenge
  • Solution
  • Benefits
  • ACS 1000 key data
  • Customer satisfaction

Specifications

Rated power per drive1765 kW (2365 hp)
Voltage options2.3 kV, 3.3 kV, 4.0 kV, 4.16 kV (optional 6.0‑6.6 kV with step‑up transformer)
Motor typeInduction motor

Frequently asked questions

How much additional electricity production was achieved after installing the ACS1000 drives?

The plant’s electricity production increased by about 35 GWh per year.

How many ACS1000 drives does Malarenergi have installed?

Malarenergi has seven ACS1000 drives and one ACS6000 drive installed.

What voltage ranges are supported by the ACS1000 drives?

The ACS1000 supports 2.3 kV to 4.16 kV, with an optional 6.0‑6.6 kV range using a step‑up transformer.