The manual begins with safety guidelines and precautions to follow before powering the unit, including proper grounding, separate power supply, and installation height requirements. It also covers pipe installation, electrical wiring, and how to correctly connect indoor and outdoor units.
Subsequent sections describe the functions of the indoor unit, LCD remote controller, airflow direction adjustment, timer settings, sleep mode, and other operating modes. Troubleshooting tips, service information, and a detailed specifications table for each model are included. This manual is written in Chinese.
| Indoor unit voltage (AM‑KY20DC) | 220 V |
|---|---|
| EER (AM‑KY20DC) | 9 |
| Indoor unit dimensions (AM‑KY20DC) | 790 × 270 × 195 mm |
| Indoor unit dimensions (AM‑KY32DC) | 1215 × 485 mm |
The indoor unit should be installed at a height of at least 2.5 m to prevent children from reaching it.
The unit must be connected to an independent power source; the power cord must not be shared with other appliances, and any damaged cord should be replaced by the service center.