Beijing Hongyuan Pengao Technology WD400 Series Temperature Monitoring Meter User Manual

WD-400 temperature monitor is a temperature monitor with a measuring range of -55℃ ~ +125℃, a temperature resolution of 0.0625℃, an upper and lower limit alarm, RS485 communication interface, 4-digit LED display, and a 10-40Vdc wide power supply.


Beijing Hongyuan Pengao Technology WD400 Series Temperature Monitoring Meter User Manual - cover page
Brand
WD
Category
Temperature sensors
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
1.2 MB
Published
09 March, 2012
Updated
30 September, 2023
MD5 checksum
9C44982A25E58694F48A481BADC75413

About this manual

The WD400 series temperature monitoring meters, produced by Beijing Hongyuan Pengao Technology, integrate temperature collection, display, alarm, control, and communication functions. The devices utilize DS18B20 digital temperature sensors and feature a 4-digit red LED display for temperature values, along with status indicators for alarms and communication.

Available models include the WD400 for single-channel measurement and the WD400B for 8-channel inspection measurement. The series supports a wide power supply range of 10-40Vdc and includes RS485 bus interfaces for connecting up to 128 meters on a single bus. This manual is written in Chinese.

What's inside

  • Technical Specifications
  • Panel Functions
  • Terminal Definitions
  • Temperature Sensors
  • Setting Instrument Address
  • Alarm Value Setting
  • Alarm Type and Hysteresis Setting
  • Sensor Login
  • Power Supply
  • Network Connection

Specifications

Temperature Measurement Range-55℃ to +125℃
Temperature Accuracy±0.5℃
Temperature Resolution0.0625℃ (12-bit)
Power Supply10-40Vdc
Communication InterfaceRS485
Communication Rate9600bps
Operating Environment-40℃ to +85℃
Dimensions70mm x 89mm x 40mm

Frequently asked questions

How many devices can be connected to a single RS485 bus?

Up to 128 WD400 meters can be connected to a single bus, with each meter having a unique 8-bit address.

What is the purpose of the alarm hysteresis setting?

Alarm hysteresis is set to prevent the alarm relay from operating frequently when the temperature fluctuates near the alarm point.

What are the differences between WD400 and WD400B models?

The WD400 supports single-channel temperature measurement, while the WD400B supports 8-channel inspection measurement.