Error codePG0

PG0 indicates the motor is outputting but there is no pulse input from the PG, or the PG wiring is broken or incorrect. The manual's first action is: “Inspect the wiring and correct it.”

Model
Yaskawa VARISPEED-616G5
Display shows
PG0
Type
Error code
Source
Manual p. 138

What PG0 means

The motor is outputting, but there is no pulse input from the PG. p. 138

Common causes

  • The motor is outputting, but there is no pulse input from the PG. p. 138
  • The PG wiring is broken. p. 138
  • The PG wiring is incorrect. p. 138
  • PG is not being powered. p. 138
  • — p. 138

What to do

  1. Inspect the wiring and correct it. p. 138
  2. Repair the broken connection. p. 138
  3. Correct the wiring. p. 138
  4. Provide proper power. p. 138
  5. Confirm whether the motor brake (holding brake) is released when in use. p. 138

Before you service the product, read the safety instructions in the manual p. 4.

If PG0 is still not resolved

  • contact Yaskawa customer service p. 4
    “有触电和火灾的危险。”
  • contact Yaskawa customer service p. 6
    “有触电的危险。”

This page summarises what the manufacturer’s manual says about PG0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.