The CarrFrg/On/Delay error occurs when the carrier frequency upper limit exceeds 5 kHz while the lower limit is ≤ 5 kHz or the proportional gain exceeds 6 or there is a parameter setting error with an abnormal set value. The manual's first action is: “Refer to operation error in section 9.1.3. Please correct.”
- Model
- Yaskawa VARISPEED-616G5
- Display shows
- CarrFrg/On/Delay (OPE11)
- Type
- Error code
- Source
- Manual p. 279
What OPE11 means
CarrFrg/On/Delay p. 280
Common causes
- Any of the following setting errors occurred: • Carrier frequency upper limit (C6‑01) > 5 kHz while carrier frequency lower limit (C6‑02) ≤ 5 kHz. • Carrier frequency proportional gain (C6‑03) > 6 but C6‑02 is set greater than C6‑01. • Upper/lower limits for C6‑01‑03 and C8‑15 are incorrect. p. 280
- Parameter setting error; the set value is abnormal p. 280
What to do
- Refer to operation error in section 9.1.3. Please correct. p. 280
Before you service the product, read the safety instructions in the manual p. 4.
If OPE11 is still not resolved
This page summarises what the manufacturer’s manual says about OPE11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.