The V/f Ptnn Setting error occurs when parameters E1‑04, E1‑06, E1‑07, and E1‑09 do not satisfy the condition E1‑04 ≥ E1‑06 > E1‑07 ≥ E1‑09 or there is a parameter setting error with an abnormal set value. The manual's first action is: “Refer to operation error in section 9.1.3. Please correct.”
- Model
- Yaskawa VARISPEED-616G5
- Display shows
- V/f Ptnn Setting (OPE10)
- Type
- Error code
- Source
- Manual p. 279
What OPE10 means
V/f Ptnn Setting p. 280
Common causes
- Parameters E1‑04, E1‑06, E1‑07, and E1‑09 do not satisfy the condition: E1‑04 (FMAX) ≥ E1‑06 (FA) > E1‑07 (FB) ≥ E1‑09 (FMIN). p. 280
- Parameter setting error; the set value is abnormal p. 280
What to do
- Refer to operation error in section 9.1.3. Please correct. p. 280
Before you service the product, read the safety instructions in the manual p. 4.
If OPE10 is still not resolved
This page summarises what the manufacturer’s manual says about OPE10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.