Error codeOPE07

The Analog Selection error occurs when H3‑05 and H3‑09 are set to the same value (except “1F”) or there is a parameter setting error with an abnormal set value. The manual's first action is: “Refer to operation error in section 9.1.3. Please correct.”

Model
Yaskawa VARISPEED-616G5
Display shows
Analog Selection (OPE07)
Type
Error code
Source
Manual p. 279

What OPE07 means

Analog Selection p. 280

Common causes

  • • H3‑05 and H3‑09 are set to the same value (except “1F”). • When using the analog command card A1‑14B, F2‑01 is set to “0”, and the multifunction input (H1‑01 to H1‑06) is set to “2” (select/inverter switching). • H3‑05 and H3‑09 are set to 2 and D respectively (2 and D cannot be set simultaneously). p. 280
  • Parameter setting error; the set value is abnormal p. 280

What to do

  1. Refer to operation error in section 9.1.3. Please correct. p. 280

Before you service the product, read the safety instructions in the manual p. 4.

If OPE07 is still not resolved

  • contact Yaskawa customer service p. 4
    “有触电和火灾的危险。”
  • contact Yaskawa customer service p. 6
    “有触电的危险。”

This page summarises what the manufacturer’s manual says about OPE07; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.